Changelog
Core
New features
Alarms: number of total/new alarms are provided as server items.
Use MariaDB 10.6 (LTS) on 64 bit machines for new installations.
New LUA functions GetItemIds and GetItemIdsRex returns array with wrong start index
Improvements
Instead of the item ID of the original item, the item ID of the Aliase is provided in the LUA function nxa.SourceItemId() now.
Trending: performance improvement for high number of interval trendings (sample, average, min, max ...).
Trending: performance improvement for high number of data changes.
Fixes
Modbus: address information is not verify properly – fixed.
BACnet: unknown abort message results in suspicious warning message – fixed.
BACnet: wrong logging of number of items – fixed.
Metering: unable to use V Links, Tasks, ... for metering items – fixed.
Startup problem on Japanese Windows systems – fixed.
Problem with V-Links for items with Turkish characters in item id – fixed.
Studio
Improvements
Clipboard functions support Unicode characters now.
Gateway Info Dialog supports Unicode characters now.
OPC Item property dialog supports Unicode characters now.
New menu entry “Open workspace path …”
Fixes
Crash if SYS.CodePage set to UTF-8 (65001) – fixed.
Saving definition table deletes all comments – fixed.
Visualization
New features
New variable "IE": ItemExists
Improvements
Editor: clipboard functions support Unicode characters now.
Editor: unicode string support in config dialogs implemented.
Editor: OPC Item property dialog supports Unicode characters now.
Editor: project language is saved and loaded from project file.
Editor: Support for Japanese char set.
Web: browser reloads webserver frontend after update
Fixes
Editor: control property "Group" not working – fixed.
Editor: Multi-Picture: stretch mode is reset if parameters are changed – fixed.
Editor: possible crash in object properties dialog during copy/paste function
PC runtime: tool-tips sometimes shows wrong value – fixed.
PC runtime: LED button: on / off disappears after switching back to page – fixed.
PC runtime: XCommand Button long down / up does not work on long running windows systems – fixed.
Web: setting variables takes too long before navigating to page – fixed.
Web: controlling of object visibility based on server items is not working properly – fixed.
Web: Visu variables are treated case-sensitive – fixed.
Web Manager
Improvements
Notify user of outdated Grms/Cloud plugin
Fixes
Metering: creating metering template: error "unit must not be empty" although it is set – fixed.
Metering: app does not show configuration parameters to apply the template – fixed.
Metering: problems with creating resource during meter point creation – fixed.
Metering: moving / removing of Cost center plan elements does not work – fixed.
GRMS: error "The Endpoint can't be reached" if using an IP address in end points URL's – fixed.
Reporting: designer does not work via https if user-defined certificate is used by web manager – fixed.
Trending: custom time range: unnecessary save question is shown – fixed.