Core

New features

  • Alarms: number of total/new alarms are provided as server items.

  • Use MariaDB 10.6 (LTS) on 64 bit machines for new installations.

Improvements

  • Instead of the item ID of the original item, the item ID of the Alias is provided in the LUA function nxa.SourceItemId() now.

  • Trending: performance improvement for high number of interval trendings (sample, average, min, max, ...).

  • Trending: performance improvement for high number of data changes.

Fixes

  • Modbus: address information is not verified properly – fixed.

  • BACnet: unknown abort message results in suspicious warning message – fixed.

  • BACnet: wrong logging of number of items – fixed.

  • Metering: unable to use V Links, Tasks, ... for metering items – fixed.

  • Startup problem on Japanese Windows systems – fixed.

  • Problem with V-Links for items with Turkish characters in item id – fixed.

  • New LUA functions GetItemIds and GetItemIdsRex returns array with wrong start index – fixed.

Studio

Improvements

  • Clipboard functions support Unicode characters now.

  • Gateway Info Dialog supports Unicode characters now.

  • OPC Item property dialog supports Unicode characters now.

  • New menu entry “Open workspace path …”.

Fixes

  • Crash if SYS.CodePage set to UTF-8 (65001) – fixed.

  • Saving definition table deletes all comments – fixed.

Visualization

New features

  • New variable "IE": ItemExists.

Improvements

  • Editor: clipboard functions support Unicode characters now.

  • Editor: Unicode string support in config dialogs implemented.

  • Editor: OPC Item property dialog supports Unicode characters now.

  • Editor: project language is saved and loaded from project file.

  • Editor: Support for Japanese char set.

  • Web: browser reloads webserver frontend after update.

Fixes

  • Editor: control property "Group" not working – fixed.

  • Editor: Multi-Picture stretch mode is reset if parameters are changed – fixed.

  • Editor: possible crash in object properties dialog during copy/paste function.

  • PC runtime: tool-tips sometimes shows wrong value – fixed.

  • PC runtime: LED button on / off disappears after switching back to page – fixed.

  • PC runtime: XCommand Button long down / up does not work on long running windows systems – fixed.

  • Web: setting variables takes too long before navigating to page – fixed.

  • Web: controlling of object visibility based on server items is not working properly – fixed.

  • Web: Visu variables are treated case-sensitive – fixed.

Web Manager

Improvements

  • Notify user of outdated Grms/Cloud plugin.

Fixes

  • Metering: creating metering template error "unit must not be empty" although it is set – fixed.

  • Metering: app does not show configuration parameters to apply the template – fixed.

  • Metering: problems with creating resource during meter point creation – fixed.

  • Metering: moving / removing of Cost center plan elements does not work – fixed.

  • GRMS: error "The Endpoint can't be reached" if using an IP address in end points URL's – fixed.

  • Reporting: designer does not work via https if user-defined certificate is used by web manager – fixed.

  • Trending: custom time range unnecessary save question is shown – fixed.

Updated Extensions

Related content

BMS Platform R2 Build 2063
BMS Platform R2 Build 2063
More like this
BMS Platform R2 Build 2010
BMS Platform R2 Build 2010
More like this
BMS Platform R2 Build 2060
BMS Platform R2 Build 2060
More like this