Zennio DALIBOX Interface 64-32

Zennio DALIBOX Interface 64-32

Supported gateways

Name

Order number

Application

Name

Order number

Application

DALIBOX Interface 64/32

ZDI-DLI

DALIBOX Interface 64/32 1.3

DALIBOX Broadcast 6CH

ZDI-DLB6

DALIBOX Broadcast 6CH 1.2

DALIBOX Broadcast 4CH

ZDI-DLB4

DALIBOX Broadcast 4CH 1.2

Configuration

In addition to the common configuration options the following configuration options are available for each channel:

parameter

type

optional/mandatory

communication object

description

default

parameter

type

optional/mandatory

communication object

description

default

Fault Power Failure

ItemId

O

KNX Object #8

True, if there is a power failure at the DALI gateway.

 

Fault Short Circuit

ItemId

O

KNX Object #9

True, if there is a short circuit at the DALI bus.

 

Fault Presence

ItemId

O

KNX Object #10

True, if at least one DALI device is missing.

 

Error Status

ItemId

M

KNX Object #11

Used to request and retrieve the error status of a DALI device.

 

Functional description

The Zennio DALIBOX Interface 64-32 supports one DALI channel with up to 64 DALI devices.

Fault information is provided by the following Server Items which are located directly under the gateway branch within the Server Item Tree:

item name

description

item name

description

KNX IP Connection

This Item reflects the KNXnet/IP tunneling connection to KNXnet/IP router or interface which is used to communicate with the KNX/DALI gateway.

Fault

True, if there is either a power failure, short circuit, presence, ballast or lamp fault.

Fault Devices

True, if there is a lamp or ballast failure for at least 1 DALI device.

Fault Ballast

True, if there is a ballast fault of one or more DALI devices on the channel. 

Fault Lamp

True, if there is a lamp fault of one or more DALI devices on the channel. 

Fault Power Failure

True, if there is a power failure within the DALI gateway.

Fault Short Circuit

True, if there is a general short circuit on the DALI channel.

Fault Presence

True, if at least one DALI device is missing on the channel.

For each configured DALI device, a sub tree with the name "Device<number>" is shown within the Server Item Tree. Each device has the following Server Items:

item name

description

item name

description

Name

Human-readable name of the DALI device. The default name is "Device<number>". This name can be changed within the Device Name Mapping Definitions. 

Fault

True, if either a lamp or a ballast fault occurred.

Fault Lamp

True, if there is a lamp fault.

Fault Ballast

True, if there is a ballast fault.

Test succeeded

True, if a response is received during the test.

 

Related content

Siemens KNX/DALI Gateway N 141/03, N 141/21, N 141/31, Legrand KNX/DALI Gateway
Siemens KNX/DALI Gateway N 141/03, N 141/21, N 141/31, Legrand KNX/DALI Gateway